2920-00-370-3012 An item having a moving plunger type core which travels parallel to the longitudinal axis of the coil(s), and which is primarily designed to perform the dual function of closing the circuit of a STARTER, ENGINE, ELECTRICAL and actuating the starter engaging mechanism. It must have provisions for attaching the mechanical linkage for actuating the engaging mechanism if the linkage is not included. May have provisions for manual actuation. Without contacts this item is known as a SOLENOID, ELECTRICAL. Without provisions for attaching mechanical linkage this item is known as a RELAY, ELECTROMAGNETIC. See also SWITCH, ENGINE STARTER, ELECTRICAL.
Alternate Parts: 1114367, 1114367, 2920-00-370-3012, 00-370-3012, 2920003703012, 003703012
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
29 | MAR 03, 1974 | 00-370-3012 | 17084 ( RELAY-SOLENOID, ENGINE STARTER, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 2920-00-370-3012
Part Number | Cage Code | Manufacturer |
---|---|---|
1114367 | 16764 | GENERAL MOTORS CORPDELCO REMY DIV |
1114367 | 1LW55 | REMY, INC. |
Technical Data | NSN 2920-00-370-3012
Characteristic | Specifications |
---|---|
NOMINAL VOLTAGE RATING | 12.0 VOLTS |
CLOSING VOLTAGE RATING | 5.0 VOLTS NOMINAL |
OPENING VOLTAGE RATING | 10.0 VOLTS NOMINAL |
PULL-IN CURRENT | 13.5 AMPERES MINIMUM AND 15.5 AMPERES MAXIMUM |
HOLD-IN CURRENT | 14.5 AMPERES MINIMUM AND 16.5 AMPERES MAXIMUM |
ENGAGING LINKAGE | NOT INCLUDED |
CONTACT MANUAL CLOSING PROVISION | NOT INCLUDED |
CONTROL TERMINAL QUANTITY | 2 |
CONTROL TERMINAL TYPE | THREADED STUD |
GROUNDED CONTROL TERMINAL | INCLUDED |
MAIN TERMINAL QUANTITY | 2 |
MAIN TERMINAL TYPE | THREADED STUD |
CONTROL TERMINAL QUANTITY INTERNALLY CONNECTED TO MAIN TERMINAL | 1 |
MOUNTING FACILITY TYPE AND QUANTITY | 2 HOLE |
MOUNTING HOLE DIAMETER | 0.270 INCHES MINIMUM AND 0.274 INCHES MAXIMUM |
MOUNTING FACILITY SPACING | HOLES SPACED 2.920 IN. C TO C 180 DEG APART |
SUBMERSIBILITY | NONSUBMERSIBLE |