NSN 2920-00-394-5999

Part Details | ENGINE GENERATOR REGULATOR


2920-00-394-5999 A regulator designed to automatically maintain the current and/or voltage output of an engine generator within specified limits, regardless of variation of load or input voltages. May include cutout relay. Does not include items in which regulation is accomplished by transformer action. See also REGULATOR, CURRENT and REGULATOR, VOLTAGE.

Alternate Parts: 1118546, 1118546, 2920-00-394-5999, 00-394-5999, 2920003945999, 003945999

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
29JAN 01, 196300-394-599917169 ( REGULATOR, ENGINE GENERATOR )
REFERENCE DRAWINGS & PICTURES

TWO PLAIN HOLES TWO SLOTTED HOLES


Cross Reference | NSN 2920-00-394-5999
Part Number Cage Code Manufacturer
111854624617GENERAL MOTORS CORP
11185467X677GENERAL MOTORS LLCDBA GENERAL MOTORS

Technical Data | NSN 2920-00-394-5999
Characteristic Specifications
SYSTEM VOLTAGE RATING24.0
SYSTEM GROUND POLARITY NEGATIVE
VOLTAGE REGULATOR UNIT TYPE WIRE WOUND COIL
VOLTAGE REGULATOR UNIT QUANTITY1
OUTPUT VOLTAGE RATING IN VOLTS27.5 MINIMUM AND 29.5 MAXIMUM
CURRENT REGULATOR UNIT TYPE WIRE WOUND COIL
CURRENT REGULATOR UNIT QUANTITY1
OUTPUT CURRENT RATING IN AMPS23.0 MINIMUM AND 27.0 MAXIMUM
CIRCUIT CONTROL DEVICE TYPE CUTOUT RELAY
CUT-IN VOLTAGE RATING25.0 MINIMUM AND 27.0 MAXIMUM
REVERSE CURRENT OVERLOAD CIRCUIT BREAKER NOT INCLUDED
FIELD RELAY UNIT NOT INCLUDED
ENVIRONMENTAL PROTECTION FUNGUS RESISTANT
RADIO INTERFERENCE SHIELDING NOT PROVIDED
TERMINAL TYPE CONNECTOR, RECEPTACLE W/EXTERNAL CONTACTS
TERMINAL QUANTITY2
TERMINAL ENCASEMENT ENCASED
CONDUIT CONNECTION QUANTITY2
MOUNTING STYLE TWO PLAIN HOLES TWO SLOTTED HOLES
MOUNTING HOLE DIAMETER0.328 INCHES NOMINAL
MOUNTING SLOT WIDTH0.328 INCHES NOMINAL
MOUNTING SLOT LENGTH0.453 INCHES NOMINAL
DISTANCE BETWEEN HOLES ALONG LENGTH6.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH6.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH5.375 INCHES NOMINAL
SHOCK MOUNT NOT PROVIDED