Part Details | ELECTRIC HEAT TREATING FURNACE
3424-00-172-4559 Excludes induction heating.
Alternate Parts: 342451122420, 3424-5112-2420, MILF80207, MILF80207TYISTACL2, MIL-F-80207TYISTACL2, 3424-00-172-4559, 00-172-4559, 3424001724559, 001724559
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 34 | SEP 01, 1972 | 00-172-4559 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-00-172-4559
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3424-5112-2420 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ |
| MILF80207 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-F-80207TYISTACL2 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 3424-00-172-4559
| Characteristic | Specifications |
|---|---|
| DESIGN TYPE | CONVECTION CAR |
| MOUNTING TYPE | FLOOR |
| MAXIMUM OPERATING TEMP | 1250.0 DEG FAHRENHEIT |
| OPERATING TEMP RANGE | +300.0 TO +1250.0 DEG FAHRENHEIT |
| TEMP CONTROL DEVICE TYPE | AUTOMATIC |
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | 220.0 |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | THREE |
| INSIDE LENGTH | 120.000 INCHES NOMINAL |
| INSIDE WIDTH | 60.000 INCHES NOMINAL |
| INSIDE HEIGHT | 60.000 INCHES NOMINAL |
| TILTING HEARTH | NOT INCLUDED |
| WORK HOLDING BASKET | NOT INCLUDED |
| DOOR/OPENING LOCATION AND QUANTITY | DOOR IN FRONT 1 |
| ACCESS OPERATION METHOD | AIR PRESSURE OPERATED DOOR |
| COUNTERWEIGHT | NOT INCLUDED |
| EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |
| TEST DATA DOCUMENT | 81349-MILF80207 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| NONDEFINITIVE SPEC/STD DATA | 1 TYPE AND A STYLE AND 2 CLASS |
| DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY PWER SUPPLY PROVIDED |