Part Details | MECHANICAL REFRIGERATION UNIT
4110-00-089-9999 A self-contained refrigeration unit having a power driven compressor, condenser, evaporator, and other necessary components. It is used to refrigerate an enclosed space by the introduction of the evaporator section through an opening in the side or top of the enclosure forming an integral section thereof (panel type) or placed in the outside proximity of the inclosure (remote type). Excludes REFRIGERATOR-FREEZER, MECHANICAL, FOOD; and REFRIGERATOR, MECHANICAL, FOOD.
Alternate Parts: PTE103, PTE10-3, MILR13312, 4110-00-089-9999, 00-089-9999, 4110000899999, 000899999
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | AUG 11, 1967 | 00-089-9999 | 13501 ( REFRIGERATION UNIT, MECHANICAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4110-00-089-9999
Part Number | Cage Code | Manufacturer |
---|---|---|
PTE10-3 | 15809 | MARSHALL ENGINEERED PRODUCTS CODBA MEPCO |
MILR13312 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 4110-00-089-9999
Characteristic | Specifications |
---|---|
UNIT TYPE | PANEL |
UNIT INSERTION LOCATION | SIDE |
INSERT PLUG SEALING SURFACE WIDTH | 38.000 INCHES |
INSERT PLUG SEALING SURFACE HEIGHT | 55.000 INCHES |
PANEL UNIT SKID MOUNTING FEATURE | NOT INCLUDED |
EVAPORATOR UNIT TYPE | FORCED AIR-COOLING |
EVAPORATOR FAN DRIVE TYPE | CONDENSING UNIT PRIME MOVER |
DEFROST SYSTEM TYPE | HOT GAS |
CONTROL TYPE | AUTOMATIC |
CONDENSER TYPE | OPEN |
CONDENSER COOLING TYPE | AIR |
FAN DRIVE TYPE | COMPRESSOR UNIT PRIME MOVER |
COOLANT TYPE | E ANY ACCEPTABLE |
COMPRESSOR DRIVE TYPE | ELECTRIC MOTOR |
HORSEPOWER RATING | 7.500 |
MOTOR CURRENT TYPE | AC |
MOTOR VOLTAGE IN VOLTS | 208.0 |
MOTOR FREQUENCY RATING | 60.0 HERTZ NOMINAL |
MOTOR PHASE | THREE |
REFRIGERATION CAPACITY IN BTU PER HOUR | 10000.0 |
RADIO INTERFERENCE SUPPRESSION | INCLUDED |
NONDEFINITIVE SPEC/STD DATA | II TYPE |