Part Details | CUBE ICE MAKING MACHINE
4110-01-047-5490 A unit which, through the process of freezing water into ice, is specifically designed to produce ice in trays in cube form through use of a grid. It must include condensing unit.
Alternate Parts: DGSC8806 TYII SZ11 GRB, DGSC-88-06 TYII SZ11 GRB, C20FASBB40S, C-20-FASB/B40-S, MILI11867, MIL-I-11867, RC306UFSS AND RB250SS, RC-306-UF-SS AND RB-250-SS, S7H4309, S7H4-309, GT301A, 4110-01-047-5490, 01-047-5490, 4110010475490, 010475490
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | SEP 09, 1977 | 01-047-5490 | 06872 ( ICE MAKING MACHINE, CUBE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4110-01-047-5490
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| DGSC-88-06 TYII SZ11 GRB | 13873 | DLA AVIATION |
| C-20-FASB/B40-S | 30130 | MILE HIGH EQUIPMENT COMPANYDBA ICE-O-MATIC |
| MIL-I-11867 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| RC-306-UF-SS AND RB-250-SS | 50689 | SCHNEIDER METAL MFG CO INCROSS TEMP DIV |
| S7H4-309 | 30617 | SNOWBIRD INDUSTRIES INC |
| GT301A | 61633 | UNIFLOW MANUFACTURING COMPANYDBA KOLD-DRAFT |
Technical Data | NSN 4110-01-047-5490
| Characteristic | Specifications |
|---|---|
| DISPENSING METHOD | MANUAL |
| ICE CAPACITY PER 24 HOUR PERIOD | 150.0 POUNDS |
| INLET WATER TEMP RATING | 70.0 DEG FAHRENHEIT |
| AMBIENT TEMP | 90.0 DEG FAHRENHEIT |
| OUTSIDE SHELL MATERIAL | STEEL, CORROSION RESISTING |
| OVERALL LENGTH | 36.000 INCHES MAXIMUM |
| OVERALL WIDTH | 38.000 INCHES MAXIMUM |
| OVERALL HEIGHT | 72.000 INCHES MAXIMUM |
| CONDENSER TYPE | ANY ACCEPTABLE |
| CONDENSER COOLING TYPE | AIR |
| EVAPORATOR UNIT TYPE | ANY ACCEPTABLE |
| COMPRESSOR TYPE | ANY ACCEPTABLE |
| COMPRESSOR ELECTRIC MOTOR HORSEPOWER RATING | 0.750 |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 115.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| INTEGRAL STORAGE BIN | INCLUDED |
| CAPACITY | 300.0 POUNDS |
| REFRIGERATION FEATURE | NOT INCLUDED |
| COOLANT TYPE | ANY ACCEPTABLE |
| DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY STORAGE CAPACITY |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY VOLTAGE RATING,FREQUENCY RATING,AND PHASE |