Part Details | VANEAXIAL FAN
4140-00-043-1981 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 0091627000, 009-1627-000, 009162700, 009-1627-00, 0091627000, 009-1627-000, 020404, A018944, A0-18944, AXIMAX1418YS MODIFIED, AXIMAX1-418YS MODIFIED, 4140-00-043-1981, 00-043-1981, 4140000431981, 000431981
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 01, 1961 | 00-043-1981 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-043-1981
Part Number | Cage Code | Manufacturer |
---|---|---|
009-1627-000 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
009-1627-00 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
009-1627-000 | 95105 | ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS |
020404 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A0-18944 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
AXIMAX1-418YS MODIFIED | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-043-1981
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 1.422 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
HOUSING INSIDE DIAMETER | 1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE AND COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 100.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 0.031 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 21000.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 55.0 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | 800.0 |
AIR FLOW RATE | 16.000 CUBIC FEET PER MINUTE MAXIMUM |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
FLOW DIRECTION | OUTWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 FLANGE |
ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF |