Part Details | VANEAXIAL FAN
4140-00-103-2449 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 5175108002, 5175108-002, 579R082H02, A074008, A0-74008, AXIMAX3591DS, AXIMAX3-591DS, AXIMAX3591DH, AXIMAX3-591DH, 4140-00-103-2449, 00-103-2449, 4140001032449, 001032449
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JUN 12, 1968 | 00-103-2449 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-103-2449
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5175108-002 | 53711 | NAVAL SEA SYSTEMS COMMAND |
| 579R082H02 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
| A0-74008 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| AXIMAX3-591DS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| AXIMAX3-591DH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-103-2449
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 2.380 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 2.660 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| PRIME MOVER POWER RATING | 0.035 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 8200.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 56.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| STAGE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |