NSN 4140-00-105-3083

Part Details | VANEAXIAL FAN


4140-00-105-3083 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.

Alternate Parts: BD2G412, BD0002G412, 13000002001, 1300000-200-1, 1000932, 100093-2, 2548582, 4509001183, 450900-1183, 1H483YS, AXIMAX1SER483YS, AXIMAX1483YS, AXIMAX1-483YS, AXIMAX1483YH, AXIMAX1-483YH, AXIMAXIH483YH, AXIMAX-IH483YH, 4140-00-105-3083, 00-105-3083, 4140001053083, 001053083

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JUL 12, 196800-105-308304245 ( FAN, VANEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED


Cross Reference | NSN 4140-00-105-3083
Part Number Cage Code Manufacturer
BD2G412D1518KRUPP ATLAS ELEKTRONIK GMBH
BD0002G412D1518KRUPP ATLAS ELEKTRONIK GMBH
1300000-200-174025MARATHONNORCO AEROSPACE, INC.DBA MARATHON BATTERY
100093-274025MARATHONNORCO AEROSPACE, INC.DBA MARATHON BATTERY
254858210001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
450900-1183D4856NORTHROP GRUMMAN LITEF GMBHDBA LITEF
1H483YS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
AXIMAX1SER483YS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
AXIMAX1-483YS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
AXIMAX1-483YH82877ROTRON INCORPORATEDDBA AMETEK ROTRON
AXIMAX-IH483YHD9182ZF INDUSTRIEANTRIEBE WITTEN GMBH

Technical Data | NSN 4140-00-105-3083
Characteristic Specifications
STYLE DESIGNATOR FIXED
DIAMETER1.500 INCHES NOMINAL
LENGTH1.468 INCHES NOMINAL
HOUSING INSIDE DIAMETER1.562 INCHES NOMINAL
QUANTITY1
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER70.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING0.008 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM10000.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZ400.0
AIR FLOW RATE9.300 CUBIC FEET PER MINUTE MINIMUM
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
FLOW DIRECTION OUTWARD
STAGE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITY2 RIM
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF