NSN 4140-00-152-1569

Part Details | TUBEAXIAL FAN


4140-00-152-1569 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.

Alternate Parts: BT1305F, 9055031, 905503-1, 19A1561, A088350, A0-88350, 4140-00-152-1569, 00-152-1569, 4140001521569, 001521569

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JUN 23, 197100-152-156904244 ( FAN, TUBEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED


Cross Reference | NSN 4140-00-152-1569
Part Number Cage Code Manufacturer
BT1305F04320CURTISS-WRIGHT CONTROLS INTEGRATEDSENSING, INC.
905503-105257GENERAL DYNAMICS LAND SYSTEMS-CANADA CORPORATION
19A156125140GLOBE MOTORS, INC.DBA GLOBE MOTORS
A0-8835082877ROTRON INCORPORATEDDBA AMETEK ROTRON

Technical Data | NSN 4140-00-152-1569
Characteristic Specifications
STYLE DESIGNATOR FIXED
DIAMETER2.781 INCHES NOMINAL
LENGTH1.406 INCHES NOMINAL
HOUSING INSIDE DIAMETER3.064 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER0.0 DEG CELSIUS AND 80.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING0.022 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM11500.0
VOLTAGE IN VOLTS AND CURRENT TYPE200.0 AC
PHASE THREE
FREQUENCY IN HERTZ400.0
AIR FLOW RATE60.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION FUNGUS RESISTANT AND HUMIDITY PROOF AND SALT SPRAY RESISTANT AND $DABH SHOCK PROOF
FLOW DIRECTION INWARD
MOUNTING FACILITY TYPE AND QUANTITY2 RING