Part Details | CIRCULATING FAN
4140-00-245-2715 A nonpositive displacement mechanical device having an axial fan impeller with or without a protective enclosure. It is designed to circulate air under free-airflow conditions, and may be equipped with a baffle(s) to deflect the air radially. It may be suspended from the ceiling, attached to the wall, or stand on a horizontal surface.
Alternate Parts: F2H93V2C, F2H93V-2C, 59P2376172, 59P237617-2, 58A5A602, 58A5A60-2, 58A5A60, 58A5A602, 58A5A60-2, 58A5A602, 58A5A60-2, 58A5A602, 58A5A60-2, 4140-00-245-2715, 00-245-2715, 4140002452715, 002452715
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JUN 15, 1973 | 00-245-2715 | 30260 ( FAN, CIRCULATING ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-245-2715
Part Number | Cage Code | Manufacturer |
---|---|---|
F2H93V-2C | 19070 | EASTERN AIR DEVICES INCDBA EAD MOTORS |
59P237617-2 | 98738 | HERLEY CHICAGODBA STEWART WARNER ELECTRONICS |
58A5A60-2 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
58A5A60 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
58A5A60-2 | 30003 | NAVAL AIR SYSTEMS COMMAND MANAGEDORIGINAL DESIGN ACTIVITY NOT |
58A5A60-2 | 02387 | NAVAL AIR WARFARE CENTERAIRCRAFT DIV |
58A5A60-2 | 53711 | NAVAL SEA SYSTEMS COMMAND |
Technical Data | NSN 4140-00-245-2715
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 2.340 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 125.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
PRIME MOVER POWER RATING | 0.006 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 11000.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 208.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | SHOCK PROOF |
FLOW DIRECTION | OUTWARD |