NSN 4140-00-445-3578

Part Details | TUBEAXIAL FAN


4140-00-445-3578 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.

Alternate Parts: H5Y3180, H5-Y3180, H5Y3180, H5-Y3180, 40683101, 40-683-101, 4140-00-445-3578, 00-445-3578, 4140004453578, 004453578

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41DEC 21, 197000-445-357804244 ( FAN, TUBEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED


Cross Reference | NSN 4140-00-445-3578
Part Number Cage Code Manufacturer
H5-Y3180K1344A K FANS LTD
H5-Y3180K7776AMETEK AIR TECHNOLOGY GROUP LTD
40-683-101K0802MEGGITT (UK) LTDDBA MEGGITT SENSING SYSTEMS

Technical Data | NSN 4140-00-445-3578
Characteristic Specifications
STYLE DESIGNATOR FIXED
LENGTH1.938 INCHES NOMINAL
HOUSING INSIDE DIAMETER1.813 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-65.0 DEG CELSIUS AND 85.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE WIRE LEAD
OPERATING SPEED AT RATED CAPACITY IN RPM10500.0
VOLTAGE IN VOLTS AND CURRENT TYPEC115.0$C200.0
PHASEA$C
FREQUENCY IN HERTZ400.0
AIR FLOW RATE12.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.3 INCHES OF WATER
FLOW DIRECTION INWARD
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE AND 4 UNTHREADED HOLE
SPECIAL FEATURESFLANGE AT AIR OUTLET