Part Details | CENTRIFUGAL FAN
4140-00-482-7148 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.
Alternate Parts: 40602501, 40602-501, 021754, DRFPKPS 303 CW 646XF, DRFP-KPS 303 CW 646XF, DPFPKPS303646XF, DPFP-KPS303-646XF, A076960, 4140-00-482-7148, 00-482-7148, 4140004827148, 004827148
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | FEB 01, 1971 | 00-482-7148 | 04254 ( FAN, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED, RECTANGULAR OUTLETS
Cross Reference | NSN 4140-00-482-7148
Part Number | Cage Code | Manufacturer |
---|---|---|
40602-501 | 14058 | DEWEY ELECTRONICS CORPORATION, THE |
021754 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DRFP-KPS 303 CW 646XF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DPFP-KPS303-646XF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A076960 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-482-7148
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED, RECTANGULAR OUTLETS |
WIDTH | 6.030 INCHES NOMINAL |
LENGTH | 5.560 INCHES NOMINAL |
OUTLET INSIDE WIDTH | 2.050 INCHES NOMINAL |
OUTLET INSIDE HEIGHT | 2.620 INCHES NOMINAL |
HEIGHT | 5.000 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | PARTIALLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -62.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
PRIME MOVER POWER RATING | 56.000 WATTS |
OPERATING SPEED AT RATED CAPACITY IN RPM | 3350.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | SINGLE |
AIR FLOW RATE | 85.000 CUBIC FEET PER MINUTE MINIMUM AND 90.000 CUBIC FEET PER MINUTE MAXIMUM |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
STAGE QUANTITY | 1 |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
OUTLET LOCATION | TOP |
DISCHARGE DIRECTION | VERTICAL UP |
FEATURES PROVIDED | NONSPARKING |