Part Details | TUBEAXIAL FAN
4140-00-499-8216 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 8651251, 865125-1, 8651250001, 865125-0001, 8651250001, 865125-0001, 025593, A074774, A0-74774, 4140-00-499-8216, 00-499-8216, 4140004998216, 004998216
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JUL 02, 1974 | 00-499-8216 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-499-8216
Part Number | Cage Code | Manufacturer |
---|---|---|
865125-1 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATIONSYSTEMS DIVISION |
865125-0001 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATIONSYSTEMS DIVISION |
865125-0001 | 06481 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVIGATION AND MARITIME SYSTEMS |
025593 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A0-74774 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-499-8216
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 1.500 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 4.500 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -54.0 DEG CELSIUS AND 100.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
PRIME MOVER POWER RATING | 0.024 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 3700.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | B380.0$$B420.0 |
AIR FLOW RATE | 133.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.2 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF |
FLOW DIRECTION | OUTWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |