Part Details | CENTRIFUGAL FAN
4140-00-618-7829 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.
Alternate Parts: K18585A, K18585, 7700708P1, 7700708, 4140-00-618-7829, 00-618-7829, 4140006187829, 006187829
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 01, 1963 | 00-618-7829 | 04254 ( FAN, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED, RECTANGULAR OUTLETS
Cross Reference | NSN 4140-00-618-7829
Part Number | Cage Code | Manufacturer |
---|---|---|
K18585A | 07077 | HOWDEN BUFFALO INCDIV HOWDEN GYROL FLUID DRIVES |
K18585 | 07077 | HOWDEN BUFFALO INCDIV HOWDEN GYROL FLUID DRIVES |
7700708P1 | 03538 | LOCKHEED MARTIN CORPORATIONDIV RMS |
7700708 | 03538 | LOCKHEED MARTIN CORPORATIONDIV RMS |
Technical Data | NSN 4140-00-618-7829
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | A FIXED, RECTANGULAR OUTLETS |
WIDTH | 13.562 INCHES NOMINAL |
LENGTH | 8.344 INCHES NOMINAL |
OUTLET INSIDE DIAMETER | 3.560 INCHES NOMINAL |
HEIGHT | 6.312 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | PARTIALLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | 60.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
PRIME MOVER POWER RATING | 0.250 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 3450.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 120.0 AC |
PHASE | SINGLE |
AIR FLOW RATE | 340.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
STAGE QUANTITY | 1 |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
OUTLET LOCATION | TOP |
DISCHARGE DIRECTION | ANGULAR DOWN AND ANGULAR UP AND HORIZONTAL AND VERTICAL DOWN |