Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 01, 1960 | 00-755-6814 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-755-6814
Part Number | Cage Code | Manufacturer |
---|---|---|
6091658-1 | 03640 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
114-470 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
023433 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
PROPIMAX3B-748WS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
PROPIMAX 3B 748WH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A0-19138 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-755-6814
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 1.734 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 3.562 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | 0.0 DEG CELSIUS AND 70.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 0.040 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 7450.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
AIR FLOW RATE | 120.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF |
FLOW DIRECTION | INWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |