NSN 4140-00-838-0768

Part Details | VENTILATING FAN


4140-00-838-0768 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.

Alternate Parts: V5H0M16, V5H0-M1-6, 3921404REVA, 392-1404REVA, 4140-00-838-0768, 00-838-0768, 4140008380768, 008380768

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41DEC 09, 196600-838-076804262 ( FAN, VENTILATING )
REFERENCE DRAWINGS & PICTURES

FIXED


Cross Reference | NSN 4140-00-838-0768
Part Number Cage Code Manufacturer
V5H0-M1-619070EASTERN AIR DEVICES INCDBA EAD MOTORS
392-1404REVA14304HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION

Technical Data | NSN 4140-00-838-0768
Characteristic Specifications
STYLE DESIGNATOR FIXED
WIDTH4.820 INCHES MAXIMUM
LENGTH4.250 INCHES NOMINAL
HEIGHT4.820 INCHES MAXIMUM
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
ELECTRICAL CONNECTION TYPE WIRE LEAD
OPERATING SPEED AT RATED CAPACITY IN RPM3450.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZB48.0$$B63.0$$B350.0$$B450.0
AIR FLOW RATE115.0 CUBIC FEET PER MINUTE MAXIMUM
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION SHOCK PROOF
FLOW DIRECTION INWARD
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE
TEST DATA DOCUMENT14304-392-1404 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)