NSN 4140-00-856-7268

Part Details | CENTRIFUGAL FAN


4140-00-856-7268 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 910820, 0N123091, DRFPMD1504482WS, DRFPMD1504-482WS, DRFPMD1504482WF, DRFP-MD1504-482WF, DRFPMD 1504 CCW482WF, DRFP-MD 1504 CCW482WF, A018568, A0-18568, 4140-00-856-7268, 00-856-7268, 4140008567268, 008567268

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 01, 196200-856-726804254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, DUAL IMPELLER, RECTANGULAR OUTLET


Cross Reference | NSN 4140-00-856-7268
Part Number Cage Code Manufacturer
91082090536LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
0N12309198230NATIONAL SECURITY AGENCY
DRFPMD1504-482WS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFP-MD1504-482WF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFP-MD 1504 CCW482WF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
A0-1856882877ROTRON INCORPORATEDDBA AMETEK ROTRON

Technical Data | NSN 4140-00-856-7268
Characteristic Specifications
STYLE DESIGNATOR FIXED, DUAL IMPELLER, RECTANGULAR OUTLET
WIDTH5.250 INCHES NOMINAL
DIAMETER1.500 INCHES NOMINAL
LENGTH2.688 INCHES NOMINAL
OUTLET INSIDE WIDTH1.250 INCHES NOMINAL
OUTLET INSIDE HEIGHT1.375 INCHES NOMINAL
QUANTITY2
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE AND COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-54.0 DEG CELSIUS AND 85.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING0.028 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM7800.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE THREE
AIR FLOW RATE42.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
STAGE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE
OUTLET LOCATION BOTTOM
DISCHARGE DIRECTION VERTICAL DOWN
FEATURES PROVIDED NONSPARKING