NSN 4140-00-899-3086

Part Details | CENTRIFUGAL FAN


4140-00-899-3086 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 908536, 020379, A040152, A0-40152, A018660, A0-18660, ARFPNPD508CCW209JF, ARFPN-PD508CCW-209JF, 4140-00-899-3086, 00-899-3086, 4140008993086, 008993086

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 01, 196200-899-308604254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, DUAL IMPELLER, RECTANGULAR OUTLET


Cross Reference | NSN 4140-00-899-3086
Part Number Cage Code Manufacturer
90853690536LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
02037982877ROTRON INCORPORATEDDBA AMETEK ROTRON
A0-4015282877ROTRON INCORPORATEDDBA AMETEK ROTRON
A0-1866082877ROTRON INCORPORATEDDBA AMETEK ROTRON
ARFPN-PD508CCW-209JF82877ROTRON INCORPORATEDDBA AMETEK ROTRON

Technical Data | NSN 4140-00-899-3086
Characteristic Specifications
STYLE DESIGNATOR FIXED, DUAL IMPELLER, RECTANGULAR OUTLET
WIDTH15.750 INCHES NOMINAL
LENGTH9.840 INCHES NOMINAL
OUTLET INSIDE WIDTH1.422 INCHES NOMINAL
OUTLET INSIDE HEIGHT4.188 INCHES NOMINAL
HEIGHT9.160 INCHES NOMINAL
QUANTITY2
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE AND COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER0.0 DEG CELSIUS AND 50.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BOX
PRIME MOVER POWER RATING0.837 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM3850.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE THREE
FREQUENCY IN HERTZ400.0
AIR FLOW RATE620.000 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE
OUTLET LOCATIONM$DTPE
DISCHARGE DIRECTION ANGULAR DOWN AND ANGULAR UP AND HORIZONTAL AND VERTICAL DOWN AND VERTICAL UP
SPECIAL FEATURESADJUSTABLE DIRECTION OF DISCHARGE FROM FLANGED OUTLETS