NSN 4140-00-905-8331

Part Details | CENTRIFUGAL FAN


4140-00-905-8331 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 0091777010, 009-1777-010, 0091777010, 009-1777-010, 010044, DRPPXS303CW853Z1, DRPP-XS303CW-853Z1, A058107, A0-58107, 4140-00-905-8331, 00-905-8331, 4140009058331, 009058331

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 01, 196000-905-833104254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, RECTANGULAR OUTLETS


Cross Reference | NSN 4140-00-905-8331
Part Number Cage Code Manufacturer
009-1777-01013499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
009-1777-01095105ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS
01004482877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRPP-XS303CW-853Z182877ROTRON INCORPORATEDDBA AMETEK ROTRON
A0-5810782877ROTRON INCORPORATEDDBA AMETEK ROTRON

Technical Data | NSN 4140-00-905-8331
Characteristic Specifications
STYLE DESIGNATOR FIXED, RECTANGULAR OUTLETS
WIDTH6.653 INCHES NOMINAL
LENGTH5.000 INCHES NOMINAL
OUTLET INSIDE WIDTH2.625 INCHES NOMINAL
OUTLET INSIDE HEIGHT2.172 INCHES NOMINAL
HEIGHT5.562 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-40.0 DEG CELSIUS AND 70.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE WIRE LEAD
PRIME MOVER POWER RATING0.018 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM5100.0
VOLTAGE IN VOLTS AND CURRENT TYPE26.7 AC
PHASE SINGLE
AIR FLOW RATE100.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE2.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF
STAGE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE
OUTLET LOCATION TOP
DISCHARGE DIRECTION VERTICAL UP