Part Details | TUBEAXIAL FAN
4140-00-944-5190 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 2501625PC54, GF802BR2, 35946572, 3594657-2, 022181, PR0PIMAX3B815WS, PR0PIMAX3B-815WS, PROPIMAX3B815WH, PROPIMAX3B-815WH, A074955, A0-74955, 4140-00-944-5190, 00-944-5190, 4140009445190, 009445190
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | MAR 16, 1966 | 00-944-5190 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-00-944-5190
Part Number | Cage Code | Manufacturer |
---|---|---|
2501625PC54 | 94988 | COOPER INDUSTRIES INCCHAMPION AVIATION PRODUCTS |
GF802BR2 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
3594657-2 | 55794 | P D A ENGINEERING |
022181 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
PR0PIMAX3B-815WS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
PROPIMAX3B-815WH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A0-74955 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-944-5190
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
DIAMETER | 3.248 INCHES NOMINAL |
LENGTH | 2.000 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 3.500 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 128.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 0.041 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 7300.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
AIR FLOW RATE | 123.000 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
FLOW DIRECTION | OUTWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |