NSN 4140-00-968-4358

Part Details | CENTRIFUGAL FAN


4140-00-968-4358 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: DRDPIPS505CW270WS, DRDPI-PS505CW-270WS, DRDPIPS505CW270WF, DRDPI-PS505CW-270WF, A018713, A0-18713, 10049696, 4140-00-968-4358, 00-968-4358, 4140009684358, 009684358

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 01, 196200-968-435804254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, INVERTED, RECTANGULAR OUTLET


Cross Reference | NSN 4140-00-968-4358
Part Number Cage Code Manufacturer
DRDPI-PS505CW-270WS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRDPI-PS505CW-270WF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
A0-1871382877ROTRON INCORPORATEDDBA AMETEK ROTRON
1004969618876U S ARMY AVIATION AND MISSILECOMMAND

Technical Data | NSN 4140-00-968-4358
Characteristic Specifications
STYLE DESIGNATOR FIXED, INVERTED, RECTANGULAR OUTLET
WIDTH7.063 INCHES MINIMUM AND 7.187 INCHES MAXIMUM
LENGTH7.157 INCHES MINIMUM AND 7.281 INCHES MAXIMUM
OUTLET INSIDE WIDTH4.250 INCHES NOMINAL
OUTLET INSIDE HEIGHT1.420 INCHES NOMINAL
HEIGHT7.719 INCHES MINIMUM AND 7.843 INCHES MAXIMUM
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-45.0 DEG FAHRENHEIT AND 145.0 DEG FAHRENHEIT
ELECTRICAL CONNECTION TYPE WIRE LEAD
PRIME MOVER POWER RATING0.250 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM3700.0
VOLTAGE IN VOLTS AND CURRENT TYPE208.0 AC
PHASE THREE
FREQUENCY IN HERTZ400.0
AIR FLOW RATE174.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE2.5 INCHES OF WATER
ENVIRONMENTAL PROTECTION HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED INSERT
OUTLET LOCATION TOP
DISCHARGE DIRECTION VERTICAL UP