Part Details | VENTILATING FAN
4140-01-006-7314 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.
Alternate Parts: XB121, 4140-01-006-7314, 01-006-7314, 4140010067314, 010067314
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JUL 22, 1975 | 01-006-7314 | 04262 ( FAN, VENTILATING ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-01-006-7314
Part Number | Cage Code | Manufacturer |
---|---|---|
XB121 | 97409 | EMERSON ELECTRIC COBUILDER PRODUCTS DIV |
Technical Data | NSN 4140-01-006-7314
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
WIDTH | 17.250 INCHES NOMINAL |
LENGTH | 10.109 INCHES NOMINAL |
HEIGHT | 17.250 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 0.050 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 1140.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | 60.0 |
AIR FLOW RATE | 1050.0 CUBIC FEET PER MINUTE MAXIMUM |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
FLOW DIRECTION | OUTWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE |