Part Details | TUBEAXIAL FAN
4140-01-022-7608 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 010163, SPARTAN RT1525YF, 0213111511, 0213-1-1151-1, 4140-01-022-7608, 01-022-7608, 4140010227608, 010227608
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JUN 05, 1976 | 01-022-7608 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-01-022-7608
Part Number | Cage Code | Manufacturer |
---|---|---|
010163 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
SPARTAN RT1525YF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
0213-1-1151-1 | 15942 | USACECOM INTELLIGENCE ELECTRONICWARFARE SENSORS DIRECTORATE |
Technical Data | NSN 4140-01-022-7608
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 1.500 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 4.500 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | -54.0 DEG CELSIUS AND 100.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 4.200 WATTS |
OPERATING SPEED AT RATED CAPACITY IN RPM | 2000.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 16.5 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | 90.0 |
AIR FLOW RATE | 62.0 CUBIC FEET PER MINUTE NOMINAL AND 79.0 CUBIC FEET PER MINUTE NOMINAL AND 82.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF |
FLOW DIRECTION | INWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 FLANGE |
SPECIAL FEATURES | ALTITUDE RATING 10000 FT OPERATING,50000 FT NON-OPERATING,ADDITIONAL OPERATING SPEED AT RATED CAPACITY IN RPM 2300.0 AND 2500,ADDITIONAL VOLTAGES 23.5 AC @AND 30.5 AC |