Part Details | VENTILATING FAN
4140-01-023-0407 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.
Alternate Parts: 94310001, 94310-001, 94310S02, 94310-S02, K2P8621, K2P862-1, DSA524316W5439, DSA-524-316-W5439, 4140-01-023-0407, 01-023-0407, 4140010230407, 010230407
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JUN 10, 1976 | 01-023-0407 | 04262 ( FAN, VENTILATING ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-01-023-0407
Part Number | Cage Code | Manufacturer |
---|---|---|
94310-001 | 51186 | CENTURY DATA SYSTEMS |
94310-S02 | 51186 | CENTURY DATA SYSTEMS |
K2P862-1 | 06223 | KOOLTRONIC INC. |
DSA-524-316-W5439 | 06812 | TORIN CORPWESTERN DIV |
Technical Data | NSN 4140-01-023-0407
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
WIDTH | 8.500 INCHES NOMINAL |
LENGTH | 10.080 INCHES NOMINAL |
HEIGHT | 11.250 INCHES MAXIMUM |
HOUSING INSIDE DIAMETER | 5.240 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
ELECTRICAL CONNECTION TYPE | CORD W/ATTACHED PLUG |
PRIME MOVER POWER RATING | 138.0 WATTS |
OPERATING SPEED AT RATED CAPACITY IN RPM | 2600.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | C208.0$C220.0 |
PHASE | THREE |
FREQUENCY IN HERTZ | B50.0$$B60.0 |
AIR FLOW RATE | 140.000 CUBIC FEET PER MINUTE MAXIMUM |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 1.5 INCHES OF WATER |
FLOW DIRECTION | INWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 BRACKET |
FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE |
SPECIAL FEATURES | USE OF PARTS OR COMPONENTS CONTAINING POLY-CHLORINATED BIPHENYLS PCB IS PROHIBITED |