Part Details | CENTRIFUGAL FAN
4140-01-025-9699 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.
Alternate Parts: C7V181Q16C, C7V181Q-16C, 138C463H01, 023997, DRPPIAS505CW123JF, DRPPI-AS505CW-123JF, DRPPIAS505CW123JS, DRPPI-AS505-CW-123JS, 4140-01-025-9699, 01-025-9699, 4140010259699, 010259699
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | AUG 12, 1976 | 01-025-9699 | 04254 ( FAN, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED, INVERTED, RECTANGULAR OUTLET

Cross Reference | NSN 4140-01-025-9699
Part Number | Cage Code | Manufacturer |
---|---|---|
C7V181Q-16C | 04810 | ASHLAND ELECTRIC PRODUCTS, INC. |
138C463H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
023997 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DRPPI-AS505CW-123JF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DRPPI-AS505-CW-123JS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-025-9699
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED, INVERTED, RECTANGULAR OUTLET |
WIDTH | 5.270 INCHES NOMINAL |
LENGTH | 7.220 INCHES NOMINAL |
OUTLET INSIDE WIDTH | 2.750 INCHES NOMINAL |
OUTLET INSIDE HEIGHT | 1.420 INCHES NOMINAL |
HEIGHT | 7.780 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
PRIME MOVER POWER RATING | 0.127 HORSEPOWER |
OPERATING SPEED AT RATED CAPACITY IN RPM | 3300.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 208.0 AC |
PHASE | THREE |
AIR FLOW RATE | 162.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
STAGE QUANTITY | 1 |
OUTLET LOCATION | M$DTPE |
DISCHARGE DIRECTION | ANGULAR DOWN AND ANGULAR UP AND HORIZONTAL AND VERTICAL DOWN AND VERTICAL UP |
SPECIAL FEATURES | MTG MAY BE ACCOMPLISHED BY INLET DUCT CLAMP TO PROVIDE ALTERNATE BLAST DIRECTIONS,CLAMPS NOT FURNISHED,MFR METHOD OF DETERMINING IMPELLER ROTATION FOR INVERTED DESIGN ESTABLISHES ROTATION AS CW,CLASS A INSULATION MOTOR WINDINGS |