Part Details | VANEAXIAL FAN
4140-01-073-3777 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: BT1625V38, BT1625V-3-8, 582R042H09, 4140-01-073-3777, 01-073-3777, 4140010733777, 010733777
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | MAR 15, 1979 | 01-073-3777 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-01-073-3777
Part Number | Cage Code | Manufacturer |
---|---|---|
BT1625V-3-8 | 04320 | CURTISS-WRIGHT CONTROLS INTEGRATEDSENSING, INC. |
582R042H09 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
Technical Data | NSN 4140-01-073-3777
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 4.310 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 3.562 INCHES NOMINAL |
QUANTITY | 1 |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
OPERATING SPEED AT RATED CAPACITY IN RPM | 7300.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
AIR FLOW RATE | 118.000 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
CRITICALITY CODE JUSTIFICATION | AGAV |
END ITEM IDENTIFICATION | E3A AWACS |