Part Details | FLUID FILTER
4330-00-235-4345 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: 50S74WE2FF6, 50-S-74W-E-2-FF6, 20S74WE2FF6, 4330-00-235-4345, 00-235-4345, 4330002354345, 002354345
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JUN 25, 1969 | 00-235-4345 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
Y STRAINER W/THREADED COVER
Cross Reference | NSN 4330-00-235-4345
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 50-S-74W-E-2-FF6 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
| 20S74WE2FF6 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
Technical Data | NSN 4330-00-235-4345
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 4 Y STRAINER W/THREADED COVER |
| BODY LENGTH | 6.110 INCHES NOMINAL |
| BODY WIDTH | 5.435 INCHES NOMINAL |
| BODY HEIGHT | 10.360 INCHES NOMINAL |
| MESH SIZE | 200.0 |
| WIRE DIAMETER | 0.0021 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 300.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
| FIRST INTAKE THREAD SERIES DESIGNATOR | NPTF |
| FIRST INTAKE NOMINAL THREAD SIZE | 2.000 INCHES |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | NOT IDENTICAL |
| FIRST DISCHARGE THREAD SERIES DESIGNATOR | NPTF |
| FIRST DISCHARGE NOMINAL THREAD SIZE | 2.000 INCHES |
| FIRST DISCHARGE THREAD DIRECTION | RIGHT-HAND |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
| FEATURES PROVIDED | AIR BLEED VALVE AND BY-PASS VALVE AND MAGNET |
| SPECIAL FEATURES | 74.0 NOM MICRON ELEMENT; ELECTRIC DIRT ALARM R-H SIDE; 2 PSI BYPASS SPRING |