NSN 4430-00-516-2898

Part Details | ELECTRIC THERMAL DRYING OVEN


4430-00-516-2898 An oven capable of maintaining and confining heat intensities within close limits. It is designed to be used for aging, baking, curing, drying, heating and/or testing various mechanical equipment or substances.

Alternate Parts: 443041148998, 4430-4114-8998, W0830TY2CLB, W0830TYPE2CLASSB, W0830, 4430-00-516-2898, 00-516-2898, 4430005162898, 005162898

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
44JAN 01, 196300-516-289812824 ( OVEN, THERMAL DRYING, ELECTRIC )
REFERENCE DRAWINGS & PICTURES

Cross Reference | NSN 4430-00-516-2898
Part Number Cage Code Manufacturer
4430-4114-899899998DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/
W0830TY2CLB81348FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES
W0830TYPE2CLASSB81348FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES
W083081348FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES

Technical Data | NSN 4430-00-516-2898
Characteristic Specifications
CIRCULATION METHOD FORCED
WORK PROTECTION FROM HEAT SOURCE COMPLETE
WATTAGE RATING40.0 KILOWATTS
CURRENT TYPE AC
VOLTAGE IN VOLTSB110.0$$B220.0
FREQUENCY IN HERTZ60.0
PHASE THREE
MAXIMUM OPERATING TEMP500.0 DEG FAHRENHEIT
NORMAL OPERATING TEMP RANGE+105.0 TO +500.0 DEG FAHRENHEIT
TEMP CONTROL METHOD AUTOMATIC
INSIDE WIDTH48.000 INCHES NOMINAL
INSIDE DEPTH120.000 INCHES NOMINAL
INSIDE HEIGHT60.000 INCHES NOMINAL
CABINET DOUBLE WALL CONSTRUCTION PROVIDED
INSULATED CABINET PROVIDED
CABINET DOOR QUANTITY2
CABINET EXHAUST VENT PROVIDED
ADJUSTABLE OPENING NOT PROVIDED
CABINET FRESH AIR INTAKE PROVIDED
FRESH AIR INTAKE ADJUSTABLE OPENING NOT PROVIDED
THERMOMETER TYPE MECHANICAL
ACCESSORY COMPONENTS AND QUANTITYCOMPLETE REPLACEMENT FOR HEATING ELEMENTS 1,FAN ASSY 1,INDICATOR LIGHT BULBS 2,THERMOMETER 1,THERMOSTAT,COMPLETE 1
NONDEFINITIVE SPEC/STD DATA2 TYPE AND B CLASS