Part Details | PORTABLE DUCT TYPE HEATER
4520-01-073-8309 A heater equipped with integral connection(s) for attaching duct(s) to direct heat to engine surface, railroad cars, warehouses, tents, and the like. It is equipped with a blower (fan) and must be mounted on skids, wheels, and the like or capable of being hand-carried. Excludes HEATER, SPACE.
Alternate Parts: 04100200, FC4002, FC400-2, 4520-01-073-8309, 01-073-8309, 4520010738309, 010738309
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 45 | MAR 21, 1979 | 01-073-8309 | 13028 ( HEATER, DUCT TYPE, PORTABLE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-01-073-8309
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 04100200 | 57386 | C-WAY INDUSTRIES INC |
| FC400-2 | 57386 | C-WAY INDUSTRIES INC |
Technical Data | NSN 4520-01-073-8309
| Characteristic | Specifications |
|---|---|
| HEAT DELIVERY RATE | 400000.0 BRITISH THERMAL UNIT |
| HEATING ELEMENT TYPE | COMBUSTION CHAMBER |
| HEAT MEDIUM TYPE | AIR |
| FUEL FEED METHOD | INTERNAL PUMP |
| INTEGRAL FUEL TANK CAPACITY | 35.0 GALLONS |
| FUEL TYPE | JP-4 JET FUEL AND JP-5 JET FUEL AND DF-A ARCTIC DIESEL FUEL OIL AND DF-1 WINTER DIESEL FUEL OIL AND DF-2 REGULAR DIESEL FUEL OIL |
| IGNITION METHOD | ELECTRODE |
| MOUNTING TYPE | TRAILER |
| HEIGHT | 44.000 INCHES NOMINAL |
| WIDTH | 51.500 INCHES NOMINAL |
| DEPTH | 68.500 INCHES NOMINAL |
| HEAT OUTLET QUANTITY | 1 |
| HEAT DELIVERY DIRECTION | HORIZONTAL |
| HEAT DISCHARGE OUTLET TYPE | STATIONARY |
| HEAT DIRECTING DEVICE | FLEXIBLE DUCTS |
| AIR CIRCULATION DEVICE | PROPELLER FAN |
| QUANTITY | 1 |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| MAXIMUM AIR FLOW RATE | 1500.0 CUBIC FEET PER MINUTE |
| PRIME MOVER TYPE | DIESEL ENGINE |
| CIRCULATED AIR TYPE | C$A |
| OPERATING CONTROL TYPE | HAND SWITCH |
| SPECIAL FEATURES | 12 IN. DUCT,OR 12 IN. DUCT ADAP ASSY W/ 6 IN. DUCT ADAP FOR 3,6 IN. DUCTS OR,12 IN. DUCT W/ 6 IN. DUCT ADAP & 3,6 IN. DUCTS; UNSAFE IN EXP ATM;6 OPER TEMP; MAY BE USED INS BLDG WHEN EXHAUST GASSES ARE CONDUCTED TO OSD ATM VIA ADDL PIPES CONNECTED TO THE EXHAUST |
| FUNCTIONAL DESCRIPTION | BURNS DLS OR JET FUEL TO PREHEAT ACFT ENGINES & FUSELAGE OR HEAT GND VEHICLES,MAINT. BLDG,FLD SHELTER & TEMPORARY STRUCT. PROVIDES FORCED FRESH VENTILATION W/O HEATING |
| REFERENCE DATA AND LITERATURE | TO. 35E7-2-11-11 |