Part Details | SPACE HEATER
4520-01-167-9024 A device designed to burn various types of fuel within an inclosure which protects and confines the fire. It is used for the purpose of raising the temperature of the air in its immediate vicinity. The inclosure may be vented. Excludes HEATER, DUCT TYPE, PORTABLE and HEATER, SPACE, ELECTRIC.
Alternate Parts: 313328, 181798, SDF35OFU, SDF-35-OFU, SDF35, SDF-35, IAN35V, IAN-35-V, 4520-01-167-9024, 01-167-9024, 4520011679024, 011679024
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
45 | DEC 08, 1983 | 01-167-9024 | 03228 ( HEATER, SPACE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-01-167-9024
Part Number | Cage Code | Manufacturer |
---|---|---|
313328 | 79466 | AESYS TECHNOLOGIES, L.L.C.DBA JACKSON & CHURCH HVAC GLOBAL |
181798 | 79466 | AESYS TECHNOLOGIES, L.L.C.DBA JACKSON & CHURCH HVAC GLOBAL |
SDF-35-OFU | 79466 | AESYS TECHNOLOGIES, L.L.C.DBA JACKSON & CHURCH HVAC GLOBAL |
SDF-35 | 79466 | AESYS TECHNOLOGIES, L.L.C.DBA JACKSON & CHURCH HVAC GLOBAL |
IAN-35-V | 0AF08 | INDUSTRIAL AIRSYSTEMS INC |
Technical Data | NSN 4520-01-167-9024
Characteristic | Specifications |
---|---|
HEAT DELIVERY RATE | 350000.0 BRITISH THERMAL UNIT |
HEATING ELEMENT TYPE | BURNER |
HEAT MEDIUM TYPE | AIR |
FUEL FEED METHOD | EXTERNAL PRESSURE |
FUEL TYPE | FUEL OIL |
IGNITION METHOD | PILOT |
MOUNTING TYPE | FLOOR SURFACE, FREE STANDING, DUCTED |
HEIGHT | 73.250 INCHES NOMINAL |
WIDTH | 30.125 INCHES NOMINAL |
DEPTH | 55.500 INCHES NOMINAL |
OPERATING CONTROL TYPE | HAND SWITCH |
FUEL CONSUMPTION RATE PER HOUR | 3.1 GALLONS |