Part Details | WARM AIR FURNACE
4520-01-299-2650 A central heating appliance consisting of a combustion chamber and secondary heat transferring surfaces inclosed within a jacket or casing, designed for burning various types of fuel. The resultant heat, being absorbed by air circulated over the heated surfaces by means of gravity or forced air circulation, may be distributed to various rooms of a building by the attachment of ducts and/or pipes. See also HEATER, SPACE.
Alternate Parts: SDF450FU, SDF-45-0-FU, 4520-01-299-2650, 01-299-2650, 4520012992650, 012992650
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
45 | APR 28, 1989 | 01-299-2650 | 09198 ( FURNACE, WARM AIR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-01-299-2650
Part Number | Cage Code | Manufacturer |
---|---|---|
SDF-45-0-FU | 79466 | AESYS TECHNOLOGIES, L.L.C.DBA JACKSON & CHURCH HVAC GLOBAL |
Technical Data | NSN 4520-01-299-2650
Characteristic | Specifications |
---|---|
HEAT DELIVERY RATE | 450000.0 BRITISH THERMAL UNIT |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 115.0 |
FREQUENCY IN HERTZ | 560.0 |
PHASE | SINGLE |
CURRENT RATING IN AMPS | 1.62 |
HEATING ELEMENT TYPE | BURNER |
HEAT MEDIUM TYPE | AIR |
FUEL FEED METHOD | |
FUEL TYPE | FUEL OIL |
IGNITION METHOD | ELECTRODE |
MOUNTING TYPE | FLOOR SURFACE, FREE STANDING, DUCTED |
HEIGHT | 73.250 INCHES NOMINAL |
WIDTH | 69.125 INCHES NOMINAL |
DEPTH | 30.125 INCHES NOMINAL |
HEAT OUTLET QUANTITY | 1 |
HEAT DELIVERY DIRECTION | HORIZONTAL AND VERTICAL |
HEAT DISCHARGE OUTLET TYPE | STATIONARY |
HEAT DIRECTING DEVICE | FLEXIBLE DUCTS |
AIR FILTER TYPE | REPLACEABLE PREFORMED |
VENTILATION DAMPER TYPE | AUTOMATIC |
INCLOSURE MATERIAL | STEEL |
OPERATING CONTROL TYPE | THERMOSTATIC |
FUEL CONSUMPTION RATE PER HOUR | 4.0 GALLONS |