4630-00-930-0589 An assembled unit consisting of one or more pumps internally contained in a receiver tank and powered by electric motor(s) externally mounted on cover plate of tank and automatically controlled. It is designed to handle drainage, flood water, effluent, raw sewage, or solids.

Alternate Parts: 13220E6316, 13207E1929, L32266, L32-266, 4630-00-930-0589, 00-930-0589, 4630009300589, 009300589

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
46APR 18, 196600-930-058908397 ( PUMPING UNIT, SEWAGE )
REFERENCE DRAWINGS & PICTURES

Cross Reference | NSN 4630-00-930-0589
Part Number Cage Code Manufacturer
13220E631697403CECOM LR CENTER
13207E192997403CECOM LR CENTER
L32-26696046CRANE PUMPS & SYSTEMS, INC.

Technical Data | NSN 4630-00-930-0589
Characteristic Specifications
GENERAL CHARACTERISTICS ITEM DESCRIPTIONMATL STEEL PARTS CADMIUM PLATED PER QQ-P-416,TYPE 2,CLASS 3,ALUMINUM PARTS ANODIZED,MIL-T-704,TYPE B FINISH,EXPLOSION PROOF IN ACCORDANCE WITH MIL-E-2036,WATERPROOF IN ACCORDANCE WITH MIL-E-13856,TYPE 1,CLASS 1,RADIO INTERFERENCE SUPPRESION IN ACCORDANCE WITH MIL-S-10379,RECEPTACLE WITH CORNELL DUBILIER FEED-THRU FILTER NO. NFT-109,50 VOLTS DC,35 AMP CAPACITOR,MATES WITH MS25183-12-5S CONNECTOR,10.750 IN. H,3.250 IN. NOM DIA OF BODY,NO LOAD SPEED 8000 TO 9000 RPM,NO LOAD CURRENT 6 TO 8 AMPS MAX,NO LOAD LIFE,DRY 8 HOURS CONTINUOUS MIN,FULL LOAD LIFE 1000 HOURS WITH PUMP COMPLETELY SUBMERGED,PUMPING 46 GPM AGAINST A 6 FT HEAD MIN,DUTY FLOW CONTINUOUS,FREE FLOW 54 GPM,OPERATING CURRENT 20 AMPS,OPERATING VOLTAGE 27.5 VOLTS DC,APPROXIMATE WEIGHT 12 LBS