NSN 4810-00-136-1135

Part Details | SOLENOID VALVE


4810-00-136-1135 A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.

Alternate Parts: 71185A73081, ORS144OR23187VDC, ORS144-OR23-187VDC, 71185A73081, ORS144OR23187VDC, ORS144-OR23-187VDC, 4810-00-136-1135, 00-136-1135, 4810001361135, 001361135

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48JAN 13, 196900-136-113510998 ( VALVE, SOLENOID )
REFERENCE DRAWINGS & PICTURES

STRAIGHT THRU


Cross Reference | NSN 4810-00-136-1135
Part Number Cage Code Manufacturer
71185A7308193781PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROL DIVISION
ORS144-OR23-187VDC93781PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROL DIVISION
71185A7308181978PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION
ORS144-OR23-187VDC81978PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION

Technical Data | NSN 4810-00-136-1135
Characteristic Specifications
STYLE DESIGNATOR STRAIGHT THRU
FLOW CONTROL DEVICE DIAPHRAGM
VALVE OPERATION METHOD SOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE187.0 DC
CURRENT RATING IN AMPS0.074
FLOW CONTROL DEVICE NORMAL OPERATION POSITION OPEN
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL300.0 POUNDS PER SQUARE INCH MAXIMUM
APERTURE DIAMETER0.109 INCHES NOMINAL
MOUNTING POSITIONR$DVT