Part Details | BATTERY WATER TESTING CONDUCTIVITY CELL
4910-01-596-2230 A plastic cuplike item consisting of a base to which five (5) standard spaced contractor pins are attached, two of the pins having platinum or platinum plated electrodes firmly attached thereto inside the cup. The cup is provided with a removable cap individually fitted to the inside diameter of same. Used as a component in a battery-water tester assembly to determine whether the water to be used in storage batteries has been contaminated.
Alternate Parts: 22802215661, 228-02-21-56-61, 4910-01-596-2230, 01-596-2230, 4910015962230, 015962230
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
49 | MAY 13, 2011 | 01-596-2230 | 60264 ( CONDUCTIVITY CELL, BATTERY WATER TESTING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4910-01-596-2230
Part Number | Cage Code | Manufacturer |
---|---|---|
228-02-21-56-61 | 0U1N0 | ROSEMOUNT ANALYTICAL INC.DIV LIQUID DIVISION |
Technical Data | NSN 4910-01-596-2230
Characteristic | Specifications |
---|---|
MATERIAL | GLASS FIBER |
SPECIAL FEATURES | 3/4-IN MNPT PROCESS CONNECTION; INTEGRAL CABLE WITH ADDITIONAL SHIELDING FOR IMPROVED EMI/RFI PROTECTION |
PART NAME ASSIGNED BY CONTROLLING AGENCY | INSERTION/SUBMERSION TOROIDAL CONDUCTIVITY SENSOR |