NSN 5905-00-001-8511

Part Details | WIRE WOUND FIXED RESISTOR


5905-00-001-8511 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE.

Alternate Parts: RWR89S5R00DR, RWR89S5R00BR, MILR3900711, MILR39007-11, MILR3900711, MIL-R-39007/11, 5905-00-001-8511, 00-001-8511, 5905000018511, 000018511

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 04, 197200-001-851100010 ( RESISTOR, FIXED, WIRE WOUND )
REFERENCE DRAWINGS & PICTURES

AXIAL TERMINAL EACH END


Cross Reference | NSN 5905-00-001-8511
Part Number Cage Code Manufacturer
RWR89S5R00DR81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
RWR89S5R00BR81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MILR39007-1181349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-R-39007/1181349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY

Technical Data | NSN 5905-00-001-8511
Characteristic Specifications
ELECTRICAL RESISTANCE5.000 OHMS
RESISTANCE TOLERANCE IN PERCENTM0.100/P0.100
POWER DISSIPATION RATING IN WATTS3.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUSM50.0/P50.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUSM55.0/P275.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR4 AXIAL TERMINAL EACH END
BODY DIAMETER0.187 INCHES NOMINAL
BODY LENGTH0.560 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
TEST DATA DOCUMENT81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).