Part Details | BAND PASS FILTER
5915-00-069-2729 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 049516, 0495-16, CC049516, CC0495-16, F30886, B9165016, B9-1650-16, CSC1933T, CSC19-33T, SMC56333516, SMC563335-16, 5915-00-069-2729, 00-069-2729, 5915000692729, 000692729
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-069-2729 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-069-2729
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 0495-16 | 32840 | CONOLOG CORPORATIONDBA INIVEN |
| CC0495-16 | 32840 | CONOLOG CORPORATIONDBA INIVEN |
| F30886 | 72149 | ELECTRONIC TRANSFORMER CORP.DIV ELECTRONIC TRANSFORMER |
| B9-1650-16 | 14304 | HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION |
| CSC19-33T | 09376 | OMNITEC DATA CORPSUB OF NYTRONICS INC |
| SMC563335-16 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5915-00-069-2729
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | ZZ2.975 KILOHERTZ |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 10.5 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | ZZ2.920 KILOHERTZ AND ZZ3.030 KILOHERTZ |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | ZZ600.0 OHMS |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | ZZ600.0 OHMS |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | Q1 STANDARD TUBE BASE |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 6.688 INCHES NOMINAL |
| BODY LENGTH | 1.500 INCHES NOMINAL |
| BODY HEIGHT | 6.188 INCHES NOMINAL |
| BODY WIDTH | 1.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | ZZ2.845 KILOHERTZ AND ZZ2.920 KILOHERTZ AND ZZ3.030 KILOHERTZ AND ZZ3.105 KILOHERTZ |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | ZZ38.0 MINIMUM AND ZZ6.0 MAXIMUM AND ZZ6.0 MAXIMUM AND ZZ38.0 MINIMUM |
| OPERATING TEMP RANGE | +0.0 TO +50.0 DEG CELSIUS |
| BODY MATERIAL | METAL |