Part Details | OVERVOLTAGE ABSORBER
5920-00-099-0826 An item specifically designed to absorb and consume surges of voltage such as that resulting across contacts when breaking a circuit having an inductive load or a burst of static across a telephone receiver. It is connected in parallel with the item it is protecting. It may be made up of metallic rectifier cells or semiconductor devices connected back-to-back which may or may not be shunted by a capacitor. It may also be a single rectifier cell or semiconductor device shunted by a capacitor. Excludes metallic rectifiers which are rated for rectifying capabilities and all single unit semiconductor devices not shunted by a capacitor. For items perfoming this function by use of voltage sensitive resistors, see RESISTOR, VOLTAGE SENSITIVE. See also CUTOUT DISK, PROTECTIVE.
Alternate Parts: 69158, 69-158, S03AA09AA, S03AA09AA, 5920-00-099-0826, 00-099-0826, 5920000990826, 000990826
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) | 
|---|---|---|---|
| 59 | DEC 06, 1972 | 00-099-0826 | 21899 ( ABSORBER, OVERVOLTAGE ) | 
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5920-00-099-0826
| Part Number | Cage Code | Manufacturer | 
|---|---|---|
| 69-158 | 97520 | BASLER ELECTRIC COMPANY | 
| S03AA09AA | 59656 | DEAN TECHNOLOGY INC.DBA CKE | 
| S03AA09AA | 88725 | WESTINGHOUSE ELECTRIC CORPGENERAL CONTROL DIV | 
Technical Data | NSN 5920-00-099-0826
| Characteristic | Specifications | 
|---|---|
| POLARIZATION FEATURE | NOT INCLUDED | 
| SHUNT CAPACITOR | NOT INCLUDED | 
| OVERALL LENGTH | 2.500 INCHES MAXIMUM | 
| OVERALL WIDTH | 1.625 INCHES MAXIMUM | 
| OVERALL HEIGHT | 2.125 INCHES MAXIMUM | 
| MOUNTING METHOD | BOLT | 
| MOUNTING CONFIGURATION | ONE BOLT THROUGH CENTER OF CELLS | 
| CURRENT TYPE | AC | 
| VOLTAGE IN VOLTS | 90.0 | 
| CURRENT RATING IN AMPS | 5.0 | 
| FREQUENCY IN HERTZ | 60.0 | 
| TERMINAL TYPE | SOLDERLESS LUG | 
| TERMINAL QUANTITY | 2 | 
| ELEMENT MATERIAL | SELENIUM | 
| HERMETIC PROTECTION | NOT PROVIDED | 