NSN 5925-00-008-0550

Part Details | CIRCUIT BREAKER


5925-00-008-0550 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: L104329, D37203, 3010315, 30103-15, 5925-00-008-0550, 00-008-0550, 5925000080550, 000080550

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 09, 197200-008-055000136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE


Cross Reference | NSN 5925-00-008-0550
Part Number Cage Code Manufacturer
L10432910988CNH INDUSTRIAL AMERICA LLC
D3720310988CNH INDUSTRIAL AMERICA LLC
30103-1513445COLE HERSEE COMPANY

Technical Data | NSN 5925-00-008-0550
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD AUTOMATIC
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OVERALL LENGTH1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM
BODY WIDTH0.775 INCHES MINIMUM AND 0.786 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.673 INCHES MINIMUM AND 0.683 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.557 INCHES MINIMUM AND 1.567 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE1.365 INCHES MINIMUM AND 1.375 INCHES MAXIMUM
UNTHREADED MOUNTING HOLE DIAMETER0.215 INCHES MINIMUM AND 0.225 INCHES MAXIMUM
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED