Part Details | PRESSURE SWITCH
5930-00-004-6210 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 441263, 44126-3, 9747072C, 974707-2C, 5930-00-004-6210, 00-004-6210, 5930000046210, 000046210
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 07, 1972 | 00-004-6210 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-004-6210
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 44126-3 | 98505 | HYDRA-ELECTRIC COMPANY |
| 974707-2C | 82577 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5930-00-004-6210
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 1.549 INCHES NOMINAL |
| BODY LENGTH | 1.000 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.230 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | ABSOLUTE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BC26.00 ACTUATION POINT MINIMUM AND BC29.00 ACTUATION POINT MAXIMUM AND BC22.00 DEACTUATION POINT MINIMUM AND BC26.00 DEACTUATION POINT MAXIMUM AND BC3.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS |
| PROOF PRESSURE | 60.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | TURRET |
| MOUNTING METHOD | INLET CONNECTION |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |