Part Details | LIQUID LEVEL SWITCH
5930-00-004-8993 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: 11308485, FL28267, 5930-00-004-8993, 00-004-8993, 5930000048993, 000048993
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 14, 1972 | 00-004-8993 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-004-8993
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 11308485 | 17773 | BALLISTIC MISSILE DEFENSE SYSTEMSCOMMAND |
| FL28267 | 04034 | GEMS SENSORS INC. |
Technical Data | NSN 5930-00-004-8993
| Characteristic | Specifications |
|---|---|
| FREQUENCY RATING | A60.0 HERTZ |
| PHASE | SINGLE/THREE |
| INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES NOMINAL LOAD |
| MAXIMUM CURRENT RATING | 200.0 MILLIAMPERES NOMINAL LOAD |
| VOLTAGE RATING AT MAXIMUM RATED CURRENT | 50.0 VOLTS |
| CONTACT ARRANGEMENT | SPST,NORMALLY CLOSED,DRY |
| RELAY | NOT INCLUDED |
| OPERATING TEMP RATING | 0.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| ACTUATION METHOD | BUOYANCY |
| FLOAT QUANTITY | 3 |
| FLOAT EFFECTIVE TRAVEL | 0.500 INCHES NOMINAL |
| MOUNTING POSITION | VERTICAL |
| MOUNTING METHOD | THREAD |
| MOUNTING DIMENSIONS | MTD BY 3/8-18 NPT THD SHAFT END |
| OVERALL DIAMETER | 1.875 INCHES NOMINAL |
| TANK INSERTION LENGTH | 25.880 INCHES NOMINAL |
| SPECIAL FEATURES | THREE SWITCHES,ACTUATED AT23.500 IN.,16.880 IN.,4.880 IN. FROM TOP OF TANK |