NSN 5955-00-004-7634

Part Details | QUARTZ CRYSTAL UNIT


5955-00-004-7634 An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.

Alternate Parts: MILC309828, MILC3098-28, CR50AU830KHZ, CR50AU83-0KHZ, CR50AU83.000KHZ, CR-50A/U83.000KHZ, CR50AU, CR50AU, 5955-00-004-7634, 00-004-7634, 5955000047634, 000047634

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 07, 197200-004-763400196 ( CRYSTAL UNIT, QUARTZ )
REFERENCE DRAWINGS & PICTURES

OVAL BODY, PIN TERMINALS


Cross Reference | NSN 5955-00-004-7634
Part Number Cage Code Manufacturer
MILC3098-2881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CR50AU83-0KHZ81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CR-50A/U83.000KHZ81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CR50AU09747POWER CONTROL DEVICES INC
CR50AU03040POWER CONTROL DEVICES, INC.DBA AMERICAN TIME PRODUCTS

Technical Data | NSN 5955-00-004-7634
Characteristic Specifications
MODE OF OSCILLATION FUNDAMENTAL
CIRCUIT RESONANCE SERIES RESONANCE
SHUNT CAPACITANCE IN PICOFARADS4.2 MAXIMUM
SPECIFIED FREQUENCY83.000 KILOHERTZ
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENTM0.012/P0.012
OPERATING TEMP RANGE-40.0 TO +70.0 DEG CELSIUS
EQUIVALENT RESISTANCE VALUE IN OHMS70000.0 NOMINAL
DRIVE LEVEL RATING0.1 MILLIWATTS NOMINAL
STYLE DESIGNATOR OVAL BODY, PIN TERMINALS
OVERALL LENGTH1.774 INCHES MAXIMUM
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
OVERALL WIDTH0.757 INCHES MAXIMUM
BODY LENGTH1.526 INCHES MAXIMUM
BODY WIDTH0.725 INCHES MAXIMUM
BODY THICKNESS0.317 INCHES MAXIMUM
OVERALL THICKNESS0.352 INCHES MAXIMUM
TERMINAL DIAMETER0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.478 INCHES MINIMUM AND 0.494 INCHES MAXIMUM
HOLDER COVER MATERIAL METAL
TEST DATA DOCUMENT81349-MILC3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).