NSN 5970-00-006-1407

Part Details | ELECTRICAL INSULATION SLEEVING


5970-00-006-1407 A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (as modified); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; and TUBING, NONMETALLIC.

Alternate Parts: G5830B09, G5830B-09, CRN332, CRN3-32, CRN33204FT, CRN-3/32-0-4FT, BACT63B03, CRN3320STK, CRN-3/32-0-STK, 5970-00-006-1407, 00-006-1407, 5970000061407, 000061407

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 19, 197200-006-140700867 ( INSULATION SLEEVING, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

SHRINKABLE


Cross Reference | NSN 5970-00-006-1407
Part Number Cage Code Manufacturer
G5830B-0926512NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS
CRN3-3206090TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION
CRN-3/32-0-4FT06090TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION
BACT63B0381205THE BOEING COMPANYDBA BOEING
CRN-3/32-0-STKF0286TYCO ELECTRONICS FRANCE SAS

Technical Data | NSN 5970-00-006-1407
Characteristic Specifications
STYLE DESIGNATOR SHRINKABLE
OVERALL LENGTH4.000 FEET NOMINAL
EXPANDED INSIDE DIAMETER0.093 INCHES NOMINAL
RECOVERED INSIDE DIAMETER0.046 INCHES NOMINAL
RECOVERED WALL THICKNESS0.020 INCHES NOMINAL
MATERIAL PLASTIC POLYOLEFIN
COLOR BLUE
FLEXIBILITY SEMIRIGID
HEAT SHRINKAGE RATING IN PERCENT50.0
TEMP RATING-55.0 DEG CELSIUS AND 135.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH2600 POUNDS PER SQUARE INCH
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS1300.0
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT
RELIABILITY INDICATOR NOT ESTABLISHED