Part Details | DIRECT CURRENT MOTOR
6105-00-179-1196 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: D289C, D289, D289C, D289, 6105-00-179-1196, 00-179-1196, 6105001791196, 001791196
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-179-1196 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-179-1196
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| D289C | 17472 | EATON CORPORATIONDIV FUEL & MOTION CONTROL SYSTEMS |
| D289 | 17472 | EATON CORPORATIONDIV FUEL & MOTION CONTROL SYSTEMS |
| D289C | 72121 | EATON MOTOR SITE |
| D289 | 72121 | EATON MOTOR SITE |
Technical Data | NSN 6105-00-179-1196
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 10.782 INCHES |
| OVERALL WIDTH | 7.375 INCHES |
| OVERALL HEIGHT | 5.438 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.250 INCHES |
| INCLOSURE FEATURE | EXPLOSION PROOF |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| CURRENT RATING METHOD | LOAD |
| TORQUE RATING AND TYPE | 5.8 FOOT-POUNDS RUNNING |
| WINDING TYPE | COMPOUND WOUND |
| DUTY CYCLE | INTERMITTENT |
| TIME INTERVAL | 3.0 MINUTES MAXIMUM ON AND 3.0 MINUTES MINIMUM OFF |
| TEMP RATING | 25.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | NONVENTILATED |
| MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
| TERMINAL TYPE AND QUANTITY | 2 SOLDER LUG |
| ROTOR SPEED RATING IN RPM | 3750.0 SINGLE FULL LOAD |