Part Details | ALTERNATING CURRENT MOTOR
6105-00-236-6763 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: SSIN204561, SSIN204-561, SSIN204561, SSIN204-561, 6105-00-236-6763, 00-236-6763, 6105002366763, 002366763
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-236-6763 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-236-6763
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| SSIN204-561 | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
| SSIN204-561 | 17771 | SINGER CO THE INDUSTRIAL SEWING ANDKNITTING DIV |
Technical Data | NSN 6105-00-236-6763
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 17.063 INCHES |
| OVERALL WIDTH | 11.375 INCHES |
| OVERALL HEIGHT | 13.625 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.500 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 8.000 INCHES |
| INCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
| INCLOSURE SPECIFICATION | MIL-STD-108 |
| WINDING TYPE | INDUCTION-SQUIRREL CAGE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 50.0 OPERATING DEG CELSIUS AND 50.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | NATURAL CONVECTION VENTILATED |
| TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |