Part Details | DIRECT CURRENT MOTOR
6105-00-241-5170 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: S1171090A, S1171090A, 6105-00-241-5170, 00-241-5170, 6105002415170, 002415170
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-241-5170 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-241-5170
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| S1171090A | 79500 | WESTINGHOUSE ELECTRIC CORP |
| S1171090A | 11660 | WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT |
Technical Data | NSN 6105-00-241-5170
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 9.875 INCHES |
| OVERALL WIDTH | 6.719 INCHES |
| OVERALL HEIGHT | 9.281 INCHES |
| MOUNTING METHOD | ADJUSTABLE BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.875 INCHES |
| INCLOSURE FEATURE | DRIPPROOF-15 DEG |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | SHUNT WOUND |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 50.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | AMBIENT AIR |
| ROTOR SPEED RATING IN RPM | 1140.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | VERTICAL MOUNTING POSITION |