Part Details | ELECTRICAL MOTOR THERMAL-OVERLOAD PROTECTOR
6110-00-432-7414 A protective device specifically designed to prevent damage to an electrical motor due to failure of the motor to start, severe overloading of short duration, too frequent starting, high ambient temperature, high or low circuit voltages, failure of ventilation or any combination thereof. It is designed to be either automatically or manually reset. Excludes CIRCUIT BREAKEY; SWITCH (1), THERMOSTATIC; HEATER, THERMAL RELEASE; and RELAY (1), THERMAL.
Alternate Parts: 791092, 7910-9-2, 6110-00-432-7414, 00-432-7414, 6110004327414, 004327414
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | MAY 05, 1971 | 00-432-7414 | 60869 ( PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-00-432-7414
Part Number | Cage Code | Manufacturer |
---|---|---|
7910-9-2 | 04320 | CURTISS-WRIGHT CONTROLS INTEGRATEDSENSING, INC. |
Technical Data | NSN 6110-00-432-7414
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 1.062 INCHES NOMINAL |
OVERALL WIDTH | 0.718 INCHES NOMINAL |
OVERALL HEIGHT | 0.796 INCHES NOMINAL |
SPECIAL FEATURES | 150 DEG C OPERATING TEMPERATURE; 2.95 AMPS; 6-16 SECOND TRIP TIME |