Part Details | DIRECT CURRENT GENERATOR
6115-00-500-0671 A generator which has a characteristic of current and voltage that flows in one direction at all times and is essentially constant in value. Does not include rotary converters, dynamotors, motor-generators, generator sets, and engine accessory generators.
Alternate Parts: WW5937894, WW5999716, 59997161, 5999716-1, MILG3111A, 6115-00-500-0671, 00-500-0671, 6115005000671, 005000671
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1963 | 00-500-0671 | 00512 ( GENERATOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-500-0671
Part Number | Cage Code | Manufacturer |
---|---|---|
WW5937894 | 24446 | GENERAL ELECTRIC COMPANY |
WW5999716 | 03497 | GENERAL ELECTRIC COOUTDOOR BREAKER BUSINESS SECTION |
5999716-1 | 71669 | GENERAL ELECTRIC COSWITCHGEAR AND CONTROL DIVISION |
MILG3111A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6115-00-500-0671
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 56.875 INCHES |
OVERALL WIDTH | 61.500 INCHES |
OVERALL HEIGHT | 59.500 INCHES |
MOUNTING METHOD | FIXED BASE |
MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 29.125 INCHES |
INCLOSURE FEATURE | DRIPPROOF-15 DEG |
INCLOSURE SPECIFICATION | MIL-STD-108 |
WINDING TYPE | SHUNT WOUND |
EXCITOR TYPE | SEPARATELY EXCITED |
DUTY CYCLE | CONTINUOUS |
TEMP RATING | 50.0 OPERATING DEG CELSIUS AND 60.0 AMBIENT DEG CELSIUS |
COOLING METHOD | NATURAL CONVECTION VENTILATED |
ROTOR SPEED RATING IN RPM | 750.0 SINGLE NO LOAD |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |
SPECIAL FEATURES | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH 21.500 IN. NOM,16.000 IN. NOM |