Part Details | STEAM TURBINE GENERATOR SET
6115-00-635-2591 A generator set using a steam turbine as the prime mover.
Alternate Parts: 19J789120240V, 19J789-120-240V, 19J789240120V, 19J789-240-120V, 6115-00-635-2591, 00-635-2591, 6115006352591, 006352591
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) | 
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-635-2591 | 00478 ( GENERATOR SET, STEAM TURBINE ) | 
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-635-2591
| Part Number | Cage Code | Manufacturer | 
|---|---|---|
| 19J789-120-240V | 79500 | WESTINGHOUSE ELECTRIC CORP | 
| 19J789-240-120V | 11660 | WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT | 
Technical Data | NSN 6115-00-635-2591
| Characteristic | Specifications | 
|---|---|
| EXCITOR TYPE | SELF-EXCITED | 
| AMBIENT TEMP IN DEG CELSIUS | 50.0 | 
| TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 40.0 | 
| MANUFACTURER NAME | WESTINGHOUSE ELECTRIC CORP | 
| PRIME MOVER MANUFACTURER NAME | WESTINGHOUSE ELECTRIC CORP | 
| STEAM OPERATING PRESSURE | 200.0 POUNDS PER SQUARE INCH GAGE | 
| STEAM TEMP RATING | 750.0 DEG FAHRENHEIT | 
| TURBINE DESIGN TYPE | IMPULSE | 
| EXHAUST TYPE | NONCONDENSING | 
| STAGE TYPE | SINGLE | 
| TURBINE TO GENERATOR COUPLING METHOD | GEAR TRAIN | 
| MOUNTING TYPE | BASE | 
| OVERALL LENGTH | 71.750 INCHES NOMINAL | 
| OVERALL WIDTH | 43.000 INCHES NOMINAL | 
| OVERALL HEIGHT | 49.563 INCHES NOMINAL | 
| ACCESSORY COMPONENT QUANTITY | A1$$A1$$A1$$A1$$A1 | 
| ACCESSORY CONTROLLING AGENCY | WESTINGHOUSE ELECTRIC CORP; WESTINGHOUSE ELECTRIC CORP; NAVSHIP; NAVSHIP; NAVSHIP | 
| ACCESSORY COMPONENT NAME | REDUCTION GEAR; RHEOSTAT,GENERATOR FIELD; TURBINE AND GEAR ACCESSORIES; MECHANICAL REPAIR PARTS; ELECTRICAL REPAIR PARTS | 
| ACCESSORY IDENTIFYING NUMBER | 20-J-727 DRAWING NO. AND 9-A-3567 DRAWING NO. AND S17-G-28052-110-003 PART NO. AND S17-G-28052-110-005 PART NO. AND S17-G-28052-110-006 PART NO. | 