Part Details | GASOLINE ENGINE GENERATOR SET
6115-00-844-2052 A generator set using a gasoline engine as the prime mover. Excludes GENERATOR SET, GASOLINE ENGINE, TRAILER MOUNTED.
Alternate Parts: S12516AS, PU286G, 6115-00-844-2052, 00-844-2052, 6115008442052, 008442052
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1962 | 00-844-2052 | 00477 ( GENERATOR SET, GASOLINE ENGINE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-844-2052
Part Number | Cage Code | Manufacturer |
---|---|---|
S12516AS | 80072 | H20 TANK INCU S MOTORS DIV |
PU286G | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
Technical Data | NSN 6115-00-844-2052
Characteristic | Specifications |
---|---|
PRIME MOVER COOLING MEDIUM | LIQUID |
MOUNTING TYPE | BASE |
OVERALL LENGTH | 44.000 INCHES NOMINAL |
OVERALL WIDTH | 22.000 INCHES NOMINAL |
OVERALL HEIGHT | 31.000 INCHES NOMINAL |
CURRENT TYPE | AC |
AMBIENT TEMP IN DEG CELSIUS | 40.0 |
TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | B50.0$$B0.8 |
WINTERIZATION FEATURE | NOT INCLUDED |
HOUSING TYPE | OPEN |
PRIME MOVER STARTING METHOD | C ANY ACCEPTABLE |
AUTOMATIC STARTING FEATURE | NOT PROVIDED |
RADIO INTERFERENCE SUPPRESSION | INCLUDED |
AC WATTAGE RATING | 5.0 KILOWATTS |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | SINGLE |
LINE TO LINE VOLTAGE IN VOLTS | 120.0 |
EXCITOR TYPE | SEPARATELY EXCITED |
EXCITOR | INCLUDED |
MANUFACTURER NAME | KURZ AND ROOT |
COOLING METHOD | RADIATOR |
CRANKING VOLTAGE IN VOLTS | 6.0 |
PRIME MOVER MANUFACTURER NAME | HERCULES |
ITEM NAME ASSIGNED BY GOVERNMENT AGENCY | GENERATOR SET |