NSN 6145-00-051-4982

Part Details | ELECTRICAL POWER CABLE


6145-00-051-4982 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.

Alternate Parts: A10211, 250820, 250-820, UL62, SVT0218, SVT02-18, 6145-00-051-4982, 00-051-4982, 6145000514982, 000514982

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JAN 01, 196000-051-498200232 ( CABLE, POWER, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

ROUND


Cross Reference | NSN 6145-00-051-4982
Part Number Cage Code Manufacturer
A1021123016BASF CATALYSTS LLC
250-82088486TRIANGLE WIRE AND CABLE INC
UL6281345UNDERWRITERS LABORATORIES INC.
SVT02-1881345UNDERWRITERS LABORATORIES INC.

Technical Data | NSN 6145-00-051-4982
Characteristic Specifications
CONDUCTOR QUANTITY2
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
CROSS-SECTIONAL SHAPE STYLE ROUND
CROSS SECTION OUTSIDE DIAMETER0.250 INCHES NOMINAL